 Standard Calibration - UV/Visible Spectrophotometers

                                                                                     

Wavelength Accuracy:                      Certified Holmium Oxide & Didymium Glass Filters

Wavelength Reproducibility:               Certified Holmium Oxide & Didymium Glass Filters

Photometric Accuracy:                      Certified Neutral Density Filters 

 Photometric Reproducibility:               Certified Neutral Density Filters 

Stray Light Performance:                   Certified Stray Light Glass Cut Off Filters

Spectral Bandwidth.

Baseline Flatness.

Drift. 

                                             

 

British/European Pharmacopoeia Calibration - UV/Visible Spectrophotometers

 

Wavelength Verification:                     Certified Holmium Oxide Solution                                                         

Photometric Accuracy:                       Certified Potassium Dichromate Solution                                                               

Stray light performance:                     Certified Potassium Chloride Solution                                    

Resolution verification:                       Certified Toluene in Hexane Solution                            

 

Certified Reference Materials used to verify the performance of spectrophotometers are serialised

and issued and with calibration certificates traceable to internationally recognised regulatory authorities.

 

 

Performance Verification - Fluorescence Spectrophotometers

 

Excitation & Emission Wavelength Calibration

Sensitivity                                                                                      

Raman Band of Water Measurements

Drift & Noise                              

                                                                                                                     

 

 Standard Calibration - Absorption Microplate Readers                                 

                

Verifying Wavelength Accuracy                      

Verifying Optical Density

Verifying Linearity & Reproducibility

Checking Optical Alignment of Microplate Reader                              

                                                                                                                                                                               

Special test plates used to verify the performance of microplate readers are serialised and issued with

data sheets traceable to internationally recognised regulatory authorities.

 

 

 

.

                                                                                                                                                             